Jenbacher plants 2017-11-11
 


JENBACHER 616 GENERATORS



REFERENCE NUMBER: L-5063

JENBACHER J616GSE01 GENERATOR, 400 VOLTS, 1500 RPM, 50 Hz, YEAR 2002



YEAR: 2002

MODEL: J616GSE01

400 VOLTS

1500 RPM

STAMFORD ALTERNATOR

KVA: 1944

HOURS: 63,085



QUANTITY: 1



REFERENCE NUMBER: L-5062

JENBACHER J616GSE12 GENERATOR, 2246 KW, 400 VOLTS, 1500 RPM, 50 Hz, YEAR 2005



YEAR: 2005

MODEL: J616GSE12

2246 KW

400 VOLTS

1500 RPM

50 Hz

GAS FIRED

HOURS: 40038

WITH AVK ALTERNATOR, 400 VOLTS

CONTROL PANEL



QUANTITY: 1



REFERENCE NUMBER: L-5064

JENBACHER J616GSC02 GENERATOR, 1942 KW, 1500 RPM, 400 VOLTS, YEAR 1999



YEAR: 1999

MODEL: J616GSC02

1942 KW

1500 RPM

400 VOLTS

STAMFORD ALTERNATOR

HOURS: 15,000



QUANTITY: 1



REFERENCE NUMBER: L-5069

GE JENBACHER JMS616GSNL GAS GENERATORS, 2700 KW EACH, YEAR 2011 TO 2012



YEAR: 2011 TO 2012

MODEL: JMS616GSNL

2700 KW EACH

VOLTAGE: 11 KV



SCOPE OF SUPPLY:



S/N


Description


Qty.

1


BASIC GENERATING SET

a)


Natural Gas based Spark Ignited Gas Engine with accessories


4 Nos.

b)


Alternator, 11KV, 50 Hz , 1.0 P.F., 1500 RPM


4 Nos.

c)


Standard Tools


2 Sets

d)


Flexible Coupling for engine / alternator


4 Nos.

e)


Common Base Frame


4 Nos.

f)


Anti-Vibration isolators


4 Nos.

g)


Flexible Connections


04 Nos

2


COMBUSTION AIR INTAKE & EXHAUST SYSTEM

a)


Intake air SPLters


4 Set

b)


Exhaust silencer


4 Nos.

c)


Flexible bellow at T/C outlet ( after Turbo)


4 Set

d)


Exhaust ducting from genset to chimney (total running 15 meters per set in silencer loop only ) & flexible bellows


Lot

e)


Support structure for above referred exhaust piping


Lot

f)


Exhaust Stack / Chimney


4 Nos.

3


COOLING SYSTEM

a)


HT Pump


4 Nos.

b)


HT Water circulating pump


8 Nos.

c)


LT Pump with motor


4 Nos.

d)


Jacket water preheater


4 Nos.

e)


TCV in HT Circuit


4 Nos.

f)


Mixure intercooler water thermostat


4 Nos.

g)


Expansion water tank ( HT + LT )


4 Nos.

h)


Radiator in HT Circuit


4 Nos.

i)


interface cooler ( LT Circuit)


4 Nos.

j)


LT Cooling water distribution system


Lot

k)


Jacket Water SPLling system (HT circuit)




l)


Hot water piping from genset to VAM including pumps, valves etc.


Lot

4


LUBE OIL SYSTEM

a)


Fresh lube oil Filling system comprising of tank, pump, piping with necessary valves, bends and fittings


Lot

b)


Lube oil cooler


4 Nos.

c)


Lube oil SPLters


4 Nos.

d)


Solenoid valves for automatic oil top up


4 Nos.

e)


Arrangement for used lube oil


Lot

5


STARTING SYSTEM

a)


Starting Battery , Motor & Cables




a1)


Starting Battery, 24V


8 Nos.

a2)


Engine Electric Starter Motor


4 Nos.

a3)


Cables with clamps


Lot

b)


Charger for above 24V Battery


4 Nos.

6


FUEL GAS SYSTEM

a)


Fuel gas pipework alongwith necessary supports from the main gas valve upto the genset


Lot

b)


Gas Train Unit


4 Nos.

c)


Flexible gas pipe / hose


Lot

d)


Gas flowmeter in the gas inlet line to engine


4 Nos.

7


ELECTRICAL POWER & CONTROL SYSTEM

a)


Control Panel for Engine Management, Control and Supervision all relevant functions of gas engine, with single synchroniser.


4 Nos.

b)


Master Control Panel ( ISLAND mode/ Grid Mode)


1 No.

c)


Battery bank with charging system for GCBP




d)


Generator incomer power panel


4 Nos.

e)


PAP (plant auxiliary panel) for genset auxiliaries


1 No.

f)


Auxiliary Transformar, Bus PT and NGR Panel


Lot

g)


Earthing strips from earthing station to the earthing grid near the earthing pits


Lot

h)


Earthing strips for vendor supplied electrical installations within the GE House


Lot

8


ELECTRICAL INSTALLATION MATERIAL

a)


Power cables from alternator to the genset power panel


Lot

b)


Control and instrument cables with termination kits, lugs, cable trays / racks etc as required for interconnecting the system within the GE House between the genset and genset panel supplied by the vendor


Lot

9


GENERAL

a)


Air conditioner for the control room


1 No.

b)


Ventilation system for giving provision for combustion air and room air flow out of the power house as per vendor requirement



 
 Contact Information
Name   Mr. Shambhu Thapa 
Company   Member : NWCE Consultancy Pvt.Ltd. 
Email   Log In to See Email 
   Inquire Now 
Tel   97712314097 
Fax   97714243657 
Mobile   =9821489072 
Web   www.sarvayuconnectingworld.in 
IP   27.34.20.194 

  : 
  back to top
 Copyright © 2004 - 2017 PETROFINDER All rights reserved. :: Term of Use | Privacy Policy |